Rank: 131 based on 713 downloads (last 30 days) and 3 files submitted
photo

Pierre Giroux

E-mail
Company/University
Hydro-Quebec Research Institute (IREQ)

Personal Profile:

Pierre Giroux has been working for over 25 years as a senior engineer at IREQ real-time simulator. His work includes design, real-time simulation, and testing of controllers for HVDC systems, FACTS controllers, and power quality devices. He also performs the design, implementation, and testing of several MATLAB/SPS models.
He has a wide experience in the preparation and presentation of technical seminars and training on Power and Control Systems.

Professional Interests:
Power electronics & utility grid modeling, Real-time simulation

 

Watch this Author's files

 

Files Posted by Pierre View all
Updated   File Tags Downloads
(last 30 days)
Comments Rating
09 Oct 2012 Screenshot Grid-Connected PV Array Two demonstrations of a grid-connected PV array using SimPowerSystems. Author: Pierre Giroux pv array, boost converter, power grid, three level inverter, mppt, dcdc 575 58
  • 4.40625
4.4 | 34 ratings
12 Apr 2012 Screenshot Loss Calculation in a 3-Phase 3-Level Inverter Using SimPowerSystems and Simscape SimPowerSystems(SPS) and Simscape are used to calculate losses in a 3-phase, 3-level inverter. Author: Pierre Giroux loss calculation, thermal model, igbt module, switching losses, conduction losses, three level inverter 75 2
  • 5.0
5.0 | 1 rating
03 Apr 2012 Screenshot Loss Calculation in a Buck Converter Using SimPowerSystems and Simscape A SimPowerSystems model is used to calculate switching and conduction losses in a buck converter. Author: Pierre Giroux loss calculation, thermal model, igbt module, switching losses, conduction losses, diode 63 1
  • 5.0
5.0 | 1 rating
Comments and Ratings by Pierre
Updated File Comments Rating
10 Oct 2012 Grid-Connected PV Array Two demonstrations of a grid-connected PV array using SimPowerSystems. Author: Pierre Giroux

Hi Subesh and Buvana,
Thanks for your contribution.
The diode characteristic inside the PV Array blocks is now correctly implemented as Id=Isat*[exp(Vd/Vt)-1]. See latest update (oct. 9).

Comments and Ratings on Pierre's Files View all
Updated File Comment by Comments Rating
19 Oct 2014 Grid-Connected PV Array Two demonstrations of a grid-connected PV array using SimPowerSystems. Author: Pierre Giroux oli, Durga

Hi
My problems are similar
I am getting errors saying
1)Initialization commands cannot be evaluated
2)error in evaluating system parameters
How can I overcome this problem...

12 Oct 2014 Grid-Connected PV Array Two demonstrations of a grid-connected PV array using SimPowerSystems. Author: Pierre Giroux Mfundo

@yuvaraj Kondaswamy depending on your OS, you can download the SDK from the windows website. Afterwhich you can follow this link http://qt-project.org/wiki/Cannot_Install_Windows_SDK Thereafter execute the SDK. I hope this helps everyone else with the query.

09 Aug 2014 Grid-Connected PV Array Two demonstrations of a grid-connected PV array using SimPowerSystems. Author: Pierre Giroux Mikhail

Awesome model. Thank you so much!

06 Jul 2014 Grid-Connected PV Array Two demonstrations of a grid-connected PV array using SimPowerSystems. Author: Pierre Giroux jayimbo@gmail.com, James

I am trying to run 'PVarray_Grid_PandO_avg.mdl' as a referenced model from the Kundur two area system average model 'power_pss'. I keep getting an algebraic loop error emanating from the PV array which I have unsuccessfully tried to break using rate transitions and other means...kindly provide any pointers.

06 Jul 2014 Grid-Connected PV Array Two demonstrations of a grid-connected PV array using SimPowerSystems. Author: Pierre Giroux jayimbo@gmail.com, James

A bit more detail to my immediate prior post is that the model I am trying to run as a referenced model is the 'average model'.