Rank: 92 based on 752 downloads (last 30 days) and 3 files submitted
photo

Pierre Giroux

E-mail
Company/University
Hydro-Quebec Research Institute (IREQ)

Personal Profile:

Pierre Giroux has been working for over 25 years as a senior engineer at IREQ real-time simulator. His work includes design, real-time simulation, and testing of controllers for HVDC systems, FACTS controllers, and power quality devices. He also performs the design, implementation, and testing of several MATLAB/SPS models.
He has a wide experience in the preparation and presentation of technical seminars and training on Power and Control Systems.

Professional Interests:
Power electronics & utility grid modeling, Real-time simulation

 

Watch this Author's files

 

Files Posted by Pierre View all
Updated   File Tags Downloads
(last 30 days)
Comments Rating
09 Oct 2012 Screenshot Grid-Connected PV Array Two demonstrations of a grid-connected PV array using SimPowerSystems. Author: Pierre Giroux pv array, boost converter, power grid, three level inverter, mppt, dcdc 630 51
  • 4.32
4.3 | 26 ratings
12 Apr 2012 Screenshot Loss Calculation in a 3-Phase 3-Level Inverter Using SimPowerSystems and Simscape SimPowerSystems(SPS) and Simscape are used to calculate losses in a 3-phase, 3-level inverter. Author: Pierre Giroux loss calculation, thermal model, igbt module, switching losses, conduction losses, three level inverter 75 2
  • 5.0
5.0 | 1 rating
03 Apr 2012 Screenshot Loss Calculation in a Buck Converter Using SimPowerSystems and Simscape A SimPowerSystems model is used to calculate switching and conduction losses in a buck converter. Author: Pierre Giroux loss calculation, thermal model, igbt module, switching losses, conduction losses, diode 47 1
  • 5.0
5.0 | 1 rating
Comments and Ratings by Pierre
Updated File Comments Rating
10 Oct 2012 Grid-Connected PV Array Two demonstrations of a grid-connected PV array using SimPowerSystems. Author: Pierre Giroux

Hi Subesh and Buvana,
Thanks for your contribution.
The diode characteristic inside the PV Array blocks is now correctly implemented as Id=Isat*[exp(Vd/Vt)-1]. See latest update (oct. 9).

Comments and Ratings on Pierre's Files View all
Updated File Comment by Comments Rating
10 Mar 2014 Loss Calculation in a 3-Phase 3-Level Inverter Using SimPowerSystems and Simscape SimPowerSystems(SPS) and Simscape are used to calculate losses in a 3-phase, 3-level inverter. Author: Pierre Giroux Nakul

how thermal capacitance value is calculated from transient impedance Vs time curve ?

30 Jan 2014 Grid-Connected PV Array Two demonstrations of a grid-connected PV array using SimPowerSystems. Author: Pierre Giroux sakthigokulrajan

i am running it in 2012a but still getting error . i have to go for r2011b for this can any one help

23 Jan 2014 Grid-Connected PV Array Two demonstrations of a grid-connected PV array using SimPowerSystems. Author: Pierre Giroux GUNJAN

nice work.. sir when i run the model i am getting the constant duty ratio. it is not varying . what could be the resion pls. help me..

03 Jan 2014 Grid-Connected PV Array Two demonstrations of a grid-connected PV array using SimPowerSystems. Author: Pierre Giroux amira

30 Dec 2013 Grid-Connected PV Array Two demonstrations of a grid-connected PV array using SimPowerSystems. Author: Pierre Giroux Francesco

excellent. I'll try to modify the model in order make simulation with time step hourly based. Could you give me any tip, please?

Contact us