Main Content

Variable Translational Spring

Translational spring with variable spring stiffness

  • Variable Translational Spring block

Libraries:
Simscape / Driveline / Couplings & Drives / Springs & Dampers

Description

The Variable Translational Spring block represents a translational spring with variable stiffness. A physical signal input port provides the variable spring stiffness. The magnitude of the spring force is equal to the product of the physical signal input and the relative linear displacement between the two translational conserving ports. A minimum spring rate prevents nonphysical values.

The translational spring force satisfies the following expression:

F={Kx,KKminKminx,K<Kmin

where:

  • F is the force transmitted through the spring between the two translational conserving ports.

  • K is the spring rate coefficient.

  • Kmin is the minimum allowed spring rate.

  • x is the relative displacement between the two translational conserving ports according to x=xinit+xRxC.

  • xinit is the initial spring deformation.

  • xR is the absolute displacement of the translational conserving port R.

  • xC is the absolute displacement of the translational conserving port C.

The block applies equal and opposite spring forces on the two translational conserving ports. The sign of the spring force acting on port R is equal to the sign of the relative linear displacement between the two ports. A positive linear velocity corresponds to a positive spring force acting on port R, and a negative spring force of equal magnitude acting on port C.

Assumptions and Limitations

The block limits the value of the variable spring stiffness to remain above zero.

Variables

To set the priority and initial target values for the block variables prior to simulation, use the Initial Targets section in the block dialog box or Property Inspector. For more information, see Set Priority and Initial Target for Block Variables.

Nominal values provide a way to specify the expected magnitude of a variable in a model. Using system scaling based on nominal values increases the simulation robustness. Nominal values can come from different sources, one of which is the Nominal Values section in the block dialog box or Property Inspector. For more information, see Modify Nominal Values for a Block Variable.

Ports

Input

expand all

Physical signal input port associated with variable spring stiffness.

Conserving

expand all

Mechanical translational conserving port associated with the negative spring end. The positive direction is from port R to port C.

Mechanical translational conserving port associated with the positive spring end. The positive direction is from port R to port C.

Parameters

expand all

Minimum value allowed for the spring rate. The physical signal input saturates below the specified value.

Extended Capabilities

C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.

Version History